HT1101S 1KVAHT11
series is online double-conversion UPS with full DSP control technology. With high input and output power factor, Wide range of input voltage while input PF>99% Output PF of 0.9, more powerful load capability. Full protection of overvoltage, circuit short and over temperature LCD/LED display, monitoring all the operation status Auto fan speed adjust.Technical SpecsInput
Input voltage: 110VAC-288VAC, 100% load@>176VAC; 80% load@>154VAC; 70% load@>132VAC; 50% load@>110VAC
Input PF: ≥0.97
Input Frequency: 40Hz~70Hz
Output
Output Voltage: 220V/230V/240V
Voltage Regulation: ± 1 %
Crest Ratio: 3:1
Efficiency: 87.0%
Key Features
Capacity: 1kVA
Phase: Single Phase in, Single Phase out
Input voltage: 110VAC-288VAC, 100% load@>176VAC; 80% load@>154VAC; 70% load@>132VAC; 50% load@>110VAC
Input PF: ≥0.97
Input Frequency: 40Hz~70Hz
Output Voltage: 220V/230V/240V
HT1102S 2KVAHT1102S 2KVA
Online,Pure Sine Wave,2KVA/1.8KW,72VDC,With 6pcs 12V/7AH BatteriesHT11 series is online double-conversion UPS with full DSP control technology. With high input and output power factor, Wide range of input voltage while input PF>99%, Output PF of 0.9,more powerful load capability, Full protection of overvoltage, circuit short and over temperature, LCD/LED display, monitoring all the operation status, Auto fan speed adjustTechnical Specs INPUT
Cold Start: YES, default frequency=50Hz or settable
Acceptable Input Voltage:
1. 110VAC~288VAC
100% load@>176VAC
80% load@>154VAC
70% load@>132VAC
50% load@>110VAC
Phase: Single phase in, single phase out
Transfer Voltage Range: (200VAC/208VAC/220VAC/230VAC/240VAC)
Line low transfer 110VAC
Line low recovery 121VAC
Line high transfer 288VAC
Line high recovery 281VAC
Input Current: Rating (nominal input voltage) : 9.6A
Input Power Factor ≥0.97
Input Frequency Range 40~70Hz
OUTPUT
Frequency adaptable Settable
Power
Power (kVA) max: 2
Power (kW) max: 1.8(1.6 for 200VAC/208VAC)
Output Voltage
Waveform (Bat. Mode) Pure Sine Wave
Nominal voltage 200/208/220/230/240VAC
Voltage regulation ± 1 %
Transient response ≤5% (0% – 100% -0%)
Transient recovery ≤30ms (0% – 100% -0%)
Voltage distortion ≤2% THD, linear load , ≤ 5% THD, non-linear load
Output Frequency
Synchronization range ±5Hz default
Battery mode (50±0.1) Hz default
Transfer Time
Line mode to battery mode 0
Efficiency
Line mode with battery full charged: 91%@100% load, 88%@50% load
ECO mode: 97.0%
Battery mode: 87%@100% load, 88%@50% load
Noise (1m away) : <45dB@<60%load, 60%load
Overload Capability(Inverter) 105%~130%: Transfer to bypass after 1 mins.
150%: Transfer to bypass after 30s
Overload Capability(Battery Mode) 105%~130%:shutdown after 10s
150%:shutdown after 5s
Overload Capability (Bypass Mode) <130%: Long time
>130%&<150%:Shutdown after 10min
>150%&<180%:Shutdown after 5 seconds
Crest Ratio 3:1
Leakage current <1mA <1mA <1mA
INDICATOR & ALARM
-Display LED+LCD
-Alarm two short one long
-Fault Continuous beeping
INTERFACE
Smart RS232 Standard Cable support INVT Power Monitor Software
SNMP(option) Power Managment from SNMP Manager and Web Browser
OPTION
Intelligent Kits DB9 port, dry contact
USB B-type USB port
SNMP Kits pluggable type
Rating/Type: 12VDC/7Ah
Quantity: 6
DC Voltage: 72VDC
Back-up Time: 6mins @80% load
Battery-Low Voltage: 66VDC~70VDC depending on load
Charger
Charging voltage: float: 82VDC/boost: 84VDC
Charging current (max): 1A
Charging time: 8h recharge to 90%
Leakage current: <1mA